Critical Radiant Flux Carpet
Astm e648 10 critical radiant flux single specimen.
Critical radiant flux carpet. Euroflor grigio carpet tiles. Critical radiant flux tested to iso 9239 1. To comply with the code a building needs to be matched to a risk group which is paired with an acceptable solution. Fire test reports for a range of timber floor coverings are available here.
Plywood or particleboard should be nominated as part of the test. Standard test method for critical radiant flux of floor covering systems using a radiant heat energy source. The critical radiant heat flux is basically the lowest energy a fire requires to keep burning hence the higher the value the better. Critical radiant flux crf and smoke development rate.
1 2 this fire test response standard measures the critical radiant flux at flame out. Euroflor arkitek carpet tiles. 16 hugo johnston drive penrose auckland auckland 09 444 3234 wellington 04 569 9599. 1 1 2 this fire test response standard measures the critical radiant flux at flameout and provides a basis for estimating one.
The fire test iso 9239 1 is only for floor coverings not wall coverings. N smoke is measured over the duration of the test. N the heat energy measured at the point of extinction is the critical heat flux chf also called the critical radiant flux crf in the building code of australia. The new code in 2012 introduced a different fire test method for floor coverings.
Critical radiant flux testing pdf. Astm e648 10 critical radiant flux new york 20. Euroflor paddington carpet tiles. 1 1 1 this fire test response standard describes a procedure for measuring critical radiant flux behavior of horizontally mounted floor covering systems exposed to a flaming ignition source in a graded radiant heat energy environment within a test chamber.
Rubber flooring indent only. Astm e648 10 critical radiant flux over pad 200. Critical radiant flux crf and smoke development rate a floor covering is required to have critical radiant flux crf greater than specified values dependent on building type location within the building and whether or not a sprinkler system is. The imposed radiant flux simulates the thermal radiation levels likely to impinge on the floors of a building whose upper surfaces are heated by flames or hot gases or both from a fully developed fire in an.
It provides a basis for estimating one aspect of fire exposure behavior for floor covering systems. Astm e648 10 critical radiant flux. Carpet production as well as retailers and suppliers of goods and services to the industry. But when a carpet manufacturer tests carpet to determine crf data the carpet and substrate used e g.
Astm e648 10 critical radiant flux non carpet specimen 200.